New windows make homes dramatically more airtight — that is much of their point. But the moisture a household produces (cooking, showers, breathing: litres per day) no longer leaks out through rattly frames, so without a ventilation plan it condenses on the coldest surfaces left. This is why Building Regulations Part F ties window replacement to ventilation, and why trickle vents went from optional to normal.
What Part F requires when you replace windows
Since the 2022 changes in England, replacement windows must generally provide ventilation that is no worse than what was there before — in practice: if the old windows had trickle vents, the new ones need them at least as large; if the old windows had none, vents of a prescribed minimum size are usually still required unless the home has another compliant ventilation system (such as continuous mechanical extract or MVHR). Background ventilators are sized in equivalent area (mm²), typically 8,000mm² per habitable room and 4,000mm² for kitchens and bathrooms alongside extract fans.
Trickle vents, honestly
Nobody buys slim aluminium frames dreaming of a plastic vent — so specify them properly. Modern through-frame vents are slim, colour-matched to the profile, closable, and available in acoustic versions for noisy roads. On our window systems they mount discreetly at the head; on doors and sliders, glazed-in or frame-head options keep faces clean. A closed vent still leaks its rated background air path — that is by design; ventilation is not a tap to shut permanently.
Reading condensation like a surveyor
- Inside face of glass: humidity too high or surface too cold. New thermally broken glazing with warm-edge spacers usually ends it; persistent cases point to lifestyle moisture or inadequate extract.
- Between panes: the sealed unit has failed; the glass needs replacing, not the household's habits.
- Outside face at dawn: counter-intuitively a good sign — the outer pane is cold because so little heat escapes. It clears as the day warms.
- Walls and cold corners after new windows: the moisture moved to the next-coldest surface; the answer is ventilation and heating balance, not blaming the windows.
Getting the spec right first time
Tell us room-by-room use when you enquire — kitchens, bathrooms, bedroom occupancy — and whether extract fans or MVHR exist. The quotation then pairs vent sizes and locations with the frames, keeps sightlines tidy, and gives building control what it needs. It is a five-minute conversation through the quote form that prevents the classic January phone call.
This article is general guidance, not a project specification. Performance figures such as U-values depend on configuration and glazing, and your quotation states the tested values for your exact specification.
Get a Free Quotation
Send your sizes or drawings — itemised quotes usually within 2–3 working days.
Questions Answered
Are trickle vents mandatory on replacement windows?
Why do my new windows have condensation when the old ones didn't?
Do trickle vents make windows draughty or noisy?

Written by
SIVAL Technical Team
Aluminium systems specialists
The SIVAL technical team shares practical, evidence-based advice on aluminium windows, doors and glazing — from U-values and Building Regulations to choosing the right system for your project.